The XC-9000 system is a totally electronic network PA system based on the TCP/IP method. By leveraging the TCP/IP method, the system guarantees the effective and correct transmission of all information packets. Not just can it utilize existing local area network, such as LANs or the Web, to transfer program signals, however likewise it can likewise be released on a devoted broadcasting network.


A single-server system can sustain up to 3000 terminals and allows for web server plunging. There are no limitations on the concurrent program networks, achieving real full digital broadcasting.


System Qualities



Versatile PA System Design


The PA system architecture is simple, including service management software application, network microphones, network amplifiers, network audio speakers, and various other devices.All equipment is linked through the TCP/IP intranet protocol, enabling for adaptable configuration and simple management of the system, with free control over broadcast content, network tools, and regions via the network.


Ip Paging MicrophoneIp Paging Microphone
Comprehensive Sound Administration


The audio monitoring software application includes built-in features for producing program strategies, flexible zoning, and pre-scheduled broadcasts.It supports 24-hour programming, permitting transforming settings throughout throughout the day


Versatile Sound Resource Assistance


The system sustains various types of audio sources for sending notifications like live speech and BGM playback. Sound sources can originate from digital musical apps, CD/DVD gamers, microphones, and so on. Furthermore, the system gives diverse features of supporting different broadcasting features such as set up broadcasting, zoned broadcasting, and emergency broadcasting.


Emergency Alarm System Combination


The system has a fire alarm function and can be integrated into a smoke alarm system. When the alarm system central system receives the startling signals, the cord will certainly transfer the signal to gadgets, which activates the XC-9000, sending out signals to audio speakers


Customers could pick to preset setups to turn on full-area or zoned alarm systems in emergency situations. The alarm system voices come in several forms and can be edited catering to needs. Customers can alter language setups, upload and edit their audio resources according to specific needs, such as intruding alarm systems, fire alarms or air aid alarm systems, etc.


Emergency Alarm System Assimilation


The system has a fire alarm function and can be integrated right into an emergency alarm system. When the alarm system central system obtains the worrying signals, the wire will send the signal to devices, which activates the XC-9000, sending signals to speakers


Individuals can choose to pre-programmed settings to activate full-area or zoned alarm systems in emergencies. The alarm system voices can be found in multiple forms and can be modified accommodating demands. For example, users can alter language setups, upload and edit their audio sources according to specific demands, such as intruding alarm systems, smoke alarm or air aid alarms, and so on





App Control for System Workflow


The system enables mobile app login and use, enabling users to initiate broadcasts and various other operations to accredited terminals with the web server software application, making sure a structured and hassle-free experience.


Integrated SIP Compatibility


The system not only allows SIP phones to log in, but additionally can be connected to third-party SIP server or IPPBX, which establishes a totally integrated and compatible interaction system via smooth assimilation right into existing systems.


Open SDK


When huge task like wise park occurs, the system gives an open SDK incorporated right into third-party application systems - SPON Communications


System Framework



Key Functions


Arranged Playback


The system is able to automatically transmit according to the scheduled tasks as long as individuals post the audio documents for each amount of time of the day to the web server and create a playback schedule.


Zone Broadcasting


The system can arbitrarily split a couple of network devices into different areas to play specified audio programs or send out announcements to any type of marked location. The quantity of each device can be remotely changed.


Real-time Broadcasting


The system can transmit and record radio programs or various other outside audio sources in real-time, and at the exact same time relayed them in sync.


Fire Alarm Integration


The system can be integrated with the emergency alarm system for control. When a smoke alarm signal is caused, it immediately turns on the emergency situation program feature and supports nearby flooring alarm systems. It likewise enables for hand-operated emergency broadcasting by clicking a solitary switch.


SIP Phone Integration


The system can be integrated with SIP web servers, allowing online speech of voice broadcasting through SIP phones to send statements anytime and anywhere.


CCTV Integration


The electronic devices such as IP POE Audio speakers embraces the global standard ONVIF protocol, which allows their voices to be relayed by means of VMS systems. The terminals can also be incorporated with CCTV systems for integrated program.


Main Products



Sound Administration Software Program XC-9000


B/S architecture, supports cross-platform applications.
Covers typical broadcasting system operates, enabling dividers management.
Unified administration of terminals within the system, watching job status, and batch quantity modification, and so on.
Sustains structure multi-level web server designs, releasing monitoring according to user geographical areas.
Supplies SDK advancement bundles for secondary growth and assimilation with other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Interaction Methods: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Response: 100Hz~ 16KHz.
Running Temperature level: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Interaction Methods: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency this hyperlink Response: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Horn Audio Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Intercom: Supported, Built-in Microphone.
Operating Temperature level: -20~ 50 ℃.
Measurements: 283.1 * 224.3 * 269mm.


Network Ceiling Audio Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Communication Methods: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Operating Temperature level: -20 to 50 ° C.
Capacities: φ213 x 165mm.


Network Wall Mount Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Communication Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Response: 100Hz~ 18KHz.
Operating Temperature level: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Regularity Action: 45Hz~ 18KHz.
Operating Temperature: -10~ 55 ℃.
Dimensions: 296x140x130mm.


Network Audio Bridge GEN-3101A01


Power Supply: POE.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Frequency Response: 50Hz~ 20KHz.
Operating Temperature level: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Feedback: 60Hz~ 18KHz.
Operating Temperature level: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Zone Mixing Digital Amplifier NBS-2301


Power Supply : AIR CONDITIONER 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Communication Method : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Ratio :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Regularity Feedback :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP User Interface System NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Communication Protocol: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm system inputs, 8 alarm system outputs.
Running Temperature level: -10~ 50 ℃.
Measurements: 483x259x44mm.


Solution For Institution





Adaptable Zoning Broadcast:


The completely network terminals can realize adaptable zoning choices, enabling transmitting alerts to individual terminals or various zones ( devices).


School Bell System:


It supplies school bell system at the beginning/ending of the course - IP PA System. Multiple circumstances can be created, consisting of different arranged program jobs according to summer/winter schedule


Emergency Alarm Assimilation


It sustains combination with fire alarm systems, allowing emergency alarm signals to be incorporated into the PA system.


Classroom Audio Boosting


Terminals sustain day-to-day applications in class scenes. They can be linked to projectors or interactive white boards for audio boosting.


Ip Pa SystemIp Paging Microphone

Smart Road Lamp/Security Post



Support SIP Method:


Integrated SIP protocol for seamless combination with network interaction systems.


VMS Operatings Systems Assimilation:


Integrated ONVIF protocol for assimilation with VMS platforms.


Third-Party Assimilation:


Constructed In HTTP API for integration with 3rd party systems.


Voice Alarm System Setting Off:


Integrated in alarm system input interface for causing voice alarms with electronic cameras.


Remedy For Hotel



Area Control by Floor:


The system uses complete network setups, separating zones depending on different floors and control over each area separately.


Smoke Alarm Integration:


The system can be incorporated with smoke alarm system, allowing assimilation of fire alarm signals into the broadcasting system.


Scheduled Broadcasting:


It supports programmable scheduled broadcasting, allowing flexible setups according to different needs.


Emergency situation Broadcasting:


It sustains emergency broadcasting for the whole area, allowing one-click emergency situation interaction.


Solution For Manufacturing facility



Zone Broadcasting:


It allows relaying to any type of zone, assuring no interference between various locations.


Alarm Triggering:


Terminals have different kinds of user interfaces, making it possible for to activate alarms when gotten in touch with cams.


All Network Devices:


Implementation of fully network tools significantly reduces the problem of running such as checking original site tools on unsafe websites, and thus safeguarding individuals and residential property.


The deployment of all network tools considerably minimizes the try this website problem of procedure and maintenance management


Integrated SIP Phones:


The system can be integrated with SIP phone and broadcast notifications utilizing SIP phones at any moment and anywhere. Two-way audio talkback between SIP phones and IP POE Speakers makes it easy for checking gadgets being in office or other work environments.


The XC-9000 system is a totally electronic network PA system based on the TCP/IP method. By leveraging the TCP/IP procedure, the system ensures the proper and reliable transmission of all information packets. The system supports different types of audio resources for sending alerts like online speech and BGM playback. In enhancement, the system offers varied features of supporting numerous broadcasting functions such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be incorporated with the fire alarm system for control.

Report this page